COW Cleaning Sheet (Mold Cleaner) Series

Share this Product:
Rubber cleaner sheet loading
Load the cleaning sheet on the mold chase
Machine cleaning procesas
Close the mold chase and cure the cleaning sheet through heated compression
Post-cleaning inspection
Open the mold chase to remove the sheet and inspect for cleaning results
Repeat process until clean
Repeat process until clean
Grade Appearance (Color) Min. Torque (lb-in) Max. Torque (lb-in) Curing Time (Sec.) Recommend Shots (No.) Specific Gravity (g/cc) Fume Time (sec.)
COW – 3000 Series White 9~11 50~60 120 ~ 400 2~4 1.1 50~60
COW – 6000 Series White 9~11 40~50 120 ~ 400 3~5 1.28 40~50
COW – 9000 Series White 9~11 55~65 120 ~ 400 3~5 1.22 10~20
Rubber Cleaner (COW Series)
No. of Shots 3-5
Sheet Dimension (Dimensions may by customized according to Customer’s needs) Length: 150-300mm

Thickness: 5-10mm

*Special Thickness: 2-4mm

Mold Temp ( C) 130-230
Mold Press (KG f/cm^2) 15-150
Curing Time (Sec) 120-500
Storage & Packaging Product are ideally stored at temperatures of 5 C or below

Caution to avoid storing at locations with temperature over 30 C or under direct sunlight

Products should be ideally stored in PE Bags, 10kgs net in a carton box

Shelf-life Product have a stored at:

5 C or below: 12 months from manufacturing date

Room temperature: 3-6 months from manufacturing date

Storage & Packaging Allow the rubber cleaning sheet to acclimate to room temperature for at least 30 minute prior to use

Use the product in a well-ventilated area and with an appropriate ventilation system

Avoid direct skin contact with the hot-cured rubber sheet

Ensure safety protocols and protective measures are in place during handling